7: BSC Link Configuration Using dlicfg
DC 900-1340I 191
Table 7–2: BSC 2780/3780 ICP Link Parameters and Defaults for Using dlicfg
dlicfg Option Name Default Valid Values
dataRate 9600 75, 110, 135, 150, 300, 600, 1200, 2400, 4800, 9600, 19200,
38400, 56000 or 64000
clockSource “external” “external” or “internal”
replyTimerLen 3 1–1800
numLeadSync 3 2–8
protocol “BSC3780” “BSC3780”
parity “odd” “none”, “odd” or “even”
charSet “ebcdiccrc16” “asciilrc8”, “ebcdiccrc16”, “asciicrc16”, “ebcdicccitt0” or
“asciiccitt0”
transBlkSize 512 64–4096
dataTranslation “table1” “disable”, “table1” or “table2”
stationPri “slave” “master” or “slave”
spaceComp “no” “yes” or “no”
convMode “no” “yes” or “no”
retryLimit 3 1–127
waitBidDelay 10 0–8192
modemControl “FDX1” “HDX1”, “FDX1”, “HDX2”, “FDX2”, “HDX3”, “FDX3”,
“HDX4” or “FDX4”
safeStore “no” “yes” or “no”
messageBlocking “dataBlk” “disable” or “dataBlk”
blockChecking “exclFirst” “disable”, “exclFirst” or “inclFirst”
qLimit 0 0–4096
eomLineCtrl “reverse” “reverse”, “hold”, “permHold” or “permHoldNotify”
readSession “no” “yes” or “no”
altAck “yes” “yes” or “no”
lineTurnDelay 0 0–8192
ttdWack “normal” “disable”, “normal”, “ttdOnly” or “wackOnly”
rviHandling “continue” “continue” or “abort”